Besides an expanded thermowell material database, which contains 35 new materials, the database for process media is an important feature of the thermowell sizing tool. Wika, member of the asme workgroup performance test code ptc 19. In addition, the sizing tool makes conversions of units possible by a few clicks as well as the calculation of flow velocities in pipes. Calculate the approximate natural frequency of the thermowell as. Tempsens wake frequency calculator is easy to use and it also ensures that thermowell is designed within the dimensional limits of ptc19. Under rapidflow conditions, a wake forms behind the thermowell. In 2010, along with other vendors, users, agencies and academia, we helped the american society of mechanical engineers asme update the thermowell calculation standard from ptc 19. Wika has adapted its wake frequency calculation to the latest asme standard, ptc 19. Sometimes referred to as wake frequency calculation, the revision incorporates new elements for evaluating thermowell constructions that will reduce the chance of vibration and stress damage to the vessel, as well as avoid vibration damage to the temperature sensor it protects. Specification of any thermowell and the materials of construction are the sole responsibility of the designer of the system that incorporates the thermowell. Vmac wake frequency software new thermowell velocity design software thats easy to use and ensures you meet the new code asme ptc 19.
Guidelines for line sizing for two phase flow in horizontal pipe. For an acceptable thermowell design, the ratio of the strouhal frequency and the natural frequency shall not exceed 0. Due to the complexity of two phase flow asme ptc 19. It was 42 years ago that the american society of mechanical engineers asme published a standard for temperature measurement ptc performance test code 19. Ais 2015 sizing thermowell thermowell configuration process data calculation result geometry material medium type medium design conditions satisfactory or not max allowed flow velocity pressure flow design optimization slide 17 michele pietroni 170915 ais 2015 sizing thermowell tool per il dimensionamento del pozzetto termometrico slide. The wake frequency calculation for thermowells asme ptc from 1974 reaffirmed 1986 was widely.
The final step is an evaluation of the thermowell length based on the steady state stress. Thermowell wake frequency calculation instrumentation tools. Fea representation of a thermowell in flow with stress representation at the tip and at the root wika data sheet in 00. Do we need to perform the wake frequency calculation wfc for thermowell located on vessel mainly gasoil separator handling three phase fluid. Sole responsibility for ensuring compatibility of the process fluid with the system rests with the end user. In applications where the thermowell wake frequency calculation fails due to strouhal frequency such as in the example calculation shown below fluidics partner, okazaki, have developed the vortexwell thermowell. Thermowells thermowell design and selection criteria. Our engineers do stress calculations per asme ptc 19. The results of these calculations should only be used as a guide for thermowell design.
A wake frequency calculation is used to determine or prove the required. One of the calculations is to determine the frequency of the wake due to the vortexinduced. Operating instruction for the thermowell calculation. When fluid flows past a thermowell, low pressure vortices are formed in the wake downstream of the well. Asme formerly known as the american society of mechanical engineers is a globally recognized organization responsible for formulating standards and. A leader in thermowell calculations for over 20 years, emerson process management has been a leader in accurate thermowell calculating. Two phase flow horizontal pipe line sizing and pressure drop calculation for two phase fluid flowing through a horizontal pipe. We would like to order wake frequency calculation for a probe installed under 45 deg. Additional data is not required but will result in more accurate calculations. Operating instruction for the thermowell calculation program according to asme ptc 19. Thermowells can be supplied with a coating for chemical resistance such as teflon ptfe, pfa, fep and halar ectfe. Strength calculation for thermowells applications the wake frequency calculation for thermowells serves as mathematical proof of the strength with respect to static and dynamic stress in relation to the operating temperature and pressure special features calculation per asme ptc 19.
Vmac wake frequency software macweld machining ltd. Thermowells thermowell design and selection criteria 918 tw1 a thermowell is a pressuretight receptacle that protects and extends the life of a temperature sensor in processing applications where the sensor is not mechanically or chemically compatible with the process environment. Thermowell selection and application burns engineering. This helical design sheds vortexes normally caused by the thermowell itself and therefore cancels out the resonance failure issue. These vortices shed from alternate sides of the well and the resulting differential pressure produces two periodic forces on the thermowell. The thermowell used with your temperature sensor provides critical protection, access, and measurement integrity. The calculation determines many factors having to do with the process application, including the frequency ratio, dynamic and static stress limits, and the pressure limits. The calculation provides guidance for establishing a comparison between the shedding frequency and the natural frequency of the thermowell. Ashcroft pressure and temperature instrumentation trust. Will it be realistic to perform the calculation considering single phase flowing however in actual three phase fluid is flowing through the same. Technical description wake frequency calculations tdtp. Asme american society of mechanical engineers has revised the content of its globally accepted standard for the calculation of thermowell wake frequencies and redesigned it for better. Wake frequency calculation is used for determining the accuate lenght of thermowell.
Two papers published in the jsme international journal in. Temperature controls does not guarantee the performance of a specific. The method of calculating the thermowell natural frequency uses a simple equation, but some. This determines the maximum length the thermowell can be in order to handle the bending stress. An oscillatinglift force, transverse to the fluid flow. This calculator establishes the practical design considerations for thermowell installations in power and process piping, which also incorporates the latest theory in the areas of natural frequency, strouhal frequency, in. Online calculation tool for thermowell installations. Thermowell wake frequency calculation in accordance with. Rather than simply update the existing version of asme ptc 19. This is the third step to resolve a wfc fail if the above two methods do not help. Enrichments in the thermowell calculation tool include a larger variety of thermowell geometries, such as stepped thermowells, and the updated asme ptc 19. Maximum fluid temperature restricted to upper temperature limits of thermowell. Wake frequency calculation engineering mathematics.
Pdf cfd analysis of dhtw utilizing ve technology a helix. Chemical engineering calculations to assist process, plant operation and maintenance engineers. Ashcroft does not verify the data generated by the wake frequency calculator the. The provisions that it contained for the wake frequency calculation were based on j. Oscillating stress psi steady state stress psi pressure psi frequency hz pass or fail disclaimer.
Thermoelectra uses for thermowell wake frequency calculations the latest asme standard. The thermowell design has passed the wake frequency calculation these well design calculations are based on the asme power test code ptc 19. What has changed with the 2016 revision of the asme ptc 19. The wake frequency calculation for thermowells serves as mathematical proof. Wake frequency calculations solid drilled thermowells tdtp002 issue 1 3 calculation of thermowell stresses and verification of design suitability reputable suppliers of solid drilled thermowells for the most demanding of process applications are only too happy to provide an individual calculation of the stresses. Thermowell is provided to protect the temperature sensor from mechanical damage and corrosion. These shedding vortices impose on the thermowell, a periodic force comprising two components i a lift force, normal to direction of flow, oscillating at the wake frequency, and ii a smaller drag force, parallel to flow, oscillating at twice the wake frequency. Thermowell wake frequency calculation in accordance with the latest asme standard. The vortex shedding frequency or wake frequency is linear with flow velocity and inversely proportional to thermowell tip diameter. This calculator establishes the practical design considerations for thermowell installations in power and process piping, which also incorporates the latest theory in the areas of natural frequency. Wake frequency calculations are completed for thermowells using procedures set out in asme ptc 19. An extremely sturdy design may increase the life of the sensor but may lead to a poor. Fluid dynamics cfd and a coupled cfdfea finite element analysis software.
895 866 34 701 1185 1005 658 1048 545 922 644 1471 119 997 165 814 1250 467 254 1443 1091 741 683 1212 391 647 43 1274 196 1022 408 126 426 621 993 542 1086